#193: update iff rate > 0 and battery not full

This commit is contained in:
copycat-killer 2016-04-11 09:38:56 +02:00
parent fe8e24e5f5
commit de03791b81

View file

@ -23,114 +23,110 @@ local setmetatable = setmetatable
-- lain.widgets.bat
local function worker(args)
local bat = {}
local args = args or {}
local timeout = args.timeout or 30
local battery = args.battery or "BAT0"
local ac = args.ac or "AC0"
local notify = args.notify or "on"
local settings = args.settings or function() end
local bat = {}
local args = args or {}
local timeout = args.timeout or 30
local battery = args.battery or "BAT0"
local ac = args.ac or "AC0"
local notify = args.notify or "on"
local settings = args.settings or function() end
bat.widget = wibox.widget.textbox('')
bat.widget = wibox.widget.textbox('')
bat_notification_low_preset = {
bat_notification_low_preset = {
title = "Battery low",
text = "Plug the cable!",
timeout = 15,
fg = "#202020",
bg = "#CDCDCD"
}
text = "Plug the cable!",
timeout = 15,
fg = "#202020",
bg = "#CDCDCD"
}
bat_notification_critical_preset = {
title = "Battery exhausted",
text = "Shutdown imminent",
timeout = 15,
fg = "#000000",
bg = "#FFFFFF"
}
bat_notification_critical_preset = {
title = "Battery exhausted",
text = "Shutdown imminent",
timeout = 15,
fg = "#000000",
bg = "#FFFFFF"
}
function update()
bat_now = {
status = "Not present",
ac_status = "N/A",
perc = "N/A",
time = "N/A",
watt = "N/A"
}
function update()
bat_now = {
status = "Not present",
ac_status = "N/A",
perc = "N/A",
time = "N/A",
watt = "N/A"
}
local bstr = "/sys/class/power_supply/" .. battery
local astr = "/sys/class/power_supply/" .. ac
local present = first_line(bstr .. "/present")
local bstr = "/sys/class/power_supply/" .. battery
local astr = "/sys/class/power_supply/" .. ac
local present = first_line(bstr .. "/present")
if present == "1"
then
-- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
local rate_current = tonumber(first_line(bstr .. "/current_now"))
local rate_voltage = tonumber(first_line(bstr .. "/voltage_now"))
local rate_power = tonumber(first_line(bstr .. "/power_now"))
if present == "1"
then
-- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
local rate_current = tonumber(first_line(bstr .. "/current_now"))
local rate_voltage = tonumber(first_line(bstr .. "/voltage_now"))
local rate_power = tonumber(first_line(bstr .. "/power_now"))
-- energy_now(P)[uWh], charge_now(I)[uAh]
local energy_now = tonumber(first_line(bstr .. "/energy_now") or
first_line(bstr .. "/charge_now"))
-- energy_now(P)[uWh], charge_now(I)[uAh]
local energy_now = tonumber(first_line(bstr .. "/energy_now") or
first_line(bstr .. "/charge_now"))
-- energy_full(P)[uWh], charge_full(I)[uAh],
local energy_full = tonumber(first_line(bstr .. "/energy_full") or
first_line(bstr .. "/charge_full"))
-- energy_full(P)[uWh], charge_full(I)[uAh]
local energy_full = tonumber(first_line(bstr .. "/energy_full") or
first_line(bstr .. "/charge_full"))
local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
math.floor((energy_now / energy_full) * 100)
local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
math.floor((energy_now / energy_full) * 100)
bat_now.status = first_line(bstr .. "/status") or "N/A"
bat_now.ac_status = first_line(astr .. "/online") or "N/A"
bat_now.status = first_line(bstr .. "/status") or "N/A"
bat_now.ac_status = first_line(astr .. "/online") or "N/A"
-- update {perc,time,watt} iff rate > 0 and battery not full
if ((rate_current and rate_current > 0) or (rate_power and rate_power > 0))
and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
then
local rate_time = 0
if bat_now.status == "Charging" then
rate_time = (energy_full - energy_now) / (rate_power or rate_current)
elseif bat_now.status == "Discharging" then
rate_time = energy_now / (rate_power or rate_current)
end
-- if rate = 0 or rate not defined skip the round
if not (rate_power and rate_power > 0) and
not (rate_current and rate_current > 0) and
not (bat_now.status == "Full")
then
return
end
local hours = math.floor(rate_time)
local minutes = math.floor((rate_time - hours) * 60)
local watt = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
local rate_time = 0
if bat_now.status == "Charging" then
rate_time = (energy_full - energy_now) / (rate_power or rate_current)
elseif bat_now.status == "Discharging" then
rate_time = energy_now / (rate_power or rate_current)
end
bat_now.perc = string.format("%d", energy_percentage)
bat_now.time = string.format("%02d:%02d", hours, minutes)
bat_now.watt = string.format("%.2fW", watt)
end
end
local hours = math.floor(rate_time)
local minutes = math.floor((rate_time - hours) * 60)
local watt = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
widget = bat.widget
settings()
bat_now.perc = string.format("%d", energy_percentage)
bat_now.time = string.format("%02d:%02d", hours, minutes)
bat_now.watt = string.format("%.2fW", watt)
end
-- notifications for low and critical states
if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
local nperc = tonumber(bat_now.perc) or 100
if nperc <= 5 then
bat.id = naughty.notify({
preset = bat_notification_critical_preset,
replaces_id = bat.id,
}).id
elseif nperc <= 15 then
bat.id = naughty.notify({
preset = bat_notification_low_preset,
replaces_id = bat.id,
}).id
end
end
end
widget = bat.widget
settings()
newtimer(battery, timeout, update)
-- notifications for low and critical states
if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
local nperc = tonumber(bat_now.perc) or 100
if nperc <= 5 then
bat.id = naughty.notify({
preset = bat_notification_critical_preset,
replaces_id = bat.id,
}).id
elseif nperc <= 15 then
bat.id = naughty.notify({
preset = bat_notification_low_preset,
replaces_id = bat.id,
}).id
end
end
end
newtimer(battery, timeout, update)
return setmetatable(bat, { __index = bat.widget })
return setmetatable(bat, { __index = bat.widget })
end
return setmetatable({}, { __call = function(_, ...) return worker(...) end })