Multiple power sources may exist under /sys/class/power_supply/. Durring autodetection (get_batteries), will case the detected ac to be reset to 'AC0' if a power source not starting with BAT or AC. This change skips updating the name of the ac device if the devices does not start with 'AC'
218 lines
8.1 KiB
Lua
218 lines
8.1 KiB
Lua
--[[
|
|
|
|
Licensed under GNU General Public License v2
|
|
* (c) 2013, Luca CPZ
|
|
* (c) 2010-2012, Peter Hofmann
|
|
|
|
--]]
|
|
|
|
local helpers = require("lain.helpers")
|
|
local fs = require("gears.filesystem")
|
|
local naughty = require("naughty")
|
|
local wibox = require("wibox")
|
|
local math = math
|
|
local string = string
|
|
local ipairs = ipairs
|
|
local tonumber = tonumber
|
|
|
|
-- Battery infos
|
|
-- lain.widget.bat
|
|
|
|
local function factory(args)
|
|
local pspath = args.pspath or "/sys/class/power_supply/"
|
|
|
|
if not fs.is_dir(pspath) then
|
|
naughty.notify { text = "lain.widget.bat: invalid power supply path", timeout = 0 }
|
|
return
|
|
end
|
|
|
|
args = args or {}
|
|
|
|
local bat = { widget = args.widget or wibox.widget.textbox() }
|
|
local timeout = args.timeout or 30
|
|
local notify = args.notify or "on"
|
|
local full_notify = args.full_notify or notify
|
|
local n_perc = args.n_perc or { 5, 15 }
|
|
local batteries = args.batteries or (args.battery and {args.battery}) or {}
|
|
local ac = args.ac or "AC0"
|
|
local settings = args.settings or function() end
|
|
|
|
function bat.get_batteries()
|
|
helpers.line_callback("ls -1 " .. pspath, function(line)
|
|
local bstr = string.match(line, "BAT%w+")
|
|
if bstr then
|
|
batteries[#batteries + 1] = bstr
|
|
else
|
|
ac = string.match(line, "A%w+") or ac
|
|
end
|
|
end)
|
|
end
|
|
|
|
if #batteries == 0 then bat.get_batteries() end
|
|
|
|
bat_notification_critical_preset = {
|
|
title = "Battery exhausted",
|
|
text = "Shutdown imminent",
|
|
timeout = 15,
|
|
fg = "#000000",
|
|
bg = "#FFFFFF"
|
|
}
|
|
|
|
bat_notification_low_preset = {
|
|
title = "Battery low",
|
|
text = "Plug the cable!",
|
|
timeout = 15,
|
|
fg = "#202020",
|
|
bg = "#CDCDCD"
|
|
}
|
|
|
|
bat_notification_charged_preset = {
|
|
title = "Battery full",
|
|
text = "You can unplug the cable",
|
|
timeout = 15,
|
|
fg = "#202020",
|
|
bg = "#CDCDCD"
|
|
}
|
|
|
|
bat_now = {
|
|
status = "N/A",
|
|
ac_status = "N/A",
|
|
perc = "N/A",
|
|
time = "N/A",
|
|
watt = "N/A"
|
|
}
|
|
|
|
bat_now.n_status = {}
|
|
bat_now.n_perc = {}
|
|
for i = 1, #batteries do
|
|
bat_now.n_status[i] = "N/A"
|
|
bat_now.n_perc[i] = 0
|
|
end
|
|
|
|
-- used to notify full charge only once before discharging
|
|
local fullnotification = false
|
|
|
|
function bat.update()
|
|
local sum_rate_current = 0
|
|
local sum_rate_voltage = 0
|
|
local sum_rate_power = 0
|
|
local sum_rate_energy = 0
|
|
local sum_energy_now = 0
|
|
local sum_energy_full = 0
|
|
|
|
for i, battery in ipairs(batteries) do
|
|
local bstr = pspath .. battery
|
|
local present = helpers.first_line(bstr .. "/present")
|
|
|
|
if tonumber(present) == 1 then
|
|
-- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
|
|
local rate_current = tonumber(helpers.first_line(bstr .. "/current_now"))
|
|
local rate_voltage = tonumber(helpers.first_line(bstr .. "/voltage_now"))
|
|
local rate_power = tonumber(helpers.first_line(bstr .. "/power_now"))
|
|
|
|
-- energy_now(P)[uWh], charge_now(I)[uAh]
|
|
local energy_now = tonumber(helpers.first_line(bstr .. "/energy_now") or
|
|
helpers.first_line(bstr .. "/charge_now"))
|
|
|
|
-- energy_full(P)[uWh], charge_full(I)[uAh]
|
|
local energy_full = tonumber(helpers.first_line(bstr .. "/energy_full") or
|
|
helpers.first_line(bstr .. "/charge_full"))
|
|
|
|
local energy_percentage = tonumber(helpers.first_line(bstr .. "/capacity")) or
|
|
math.floor((energy_now / energy_full) * 100)
|
|
|
|
bat_now.n_status[i] = helpers.first_line(bstr .. "/status") or "N/A"
|
|
bat_now.n_perc[i] = energy_percentage or bat_now.n_perc[i]
|
|
|
|
sum_rate_current = sum_rate_current + (rate_current or 0)
|
|
sum_rate_voltage = sum_rate_voltage + (rate_voltage or 0)
|
|
sum_rate_power = sum_rate_power + (rate_power or 0)
|
|
sum_rate_energy = sum_rate_energy + (rate_power or (((rate_voltage or 0) * (rate_current or 0)) / 1e6))
|
|
sum_energy_now = sum_energy_now + (energy_now or 0)
|
|
sum_energy_full = sum_energy_full + (energy_full or 0)
|
|
end
|
|
end
|
|
|
|
-- When one of the battery is charging, others' status are either
|
|
-- "Full", "Unknown" or "Charging". When the laptop is not plugged in,
|
|
-- one or more of the batteries may be full, but only one battery
|
|
-- discharging suffices to set global status to "Discharging".
|
|
bat_now.status = bat_now.n_status[1] or "N/A"
|
|
for _,status in ipairs(bat_now.n_status) do
|
|
if status == "Discharging" or status == "Charging" then
|
|
bat_now.status = status
|
|
end
|
|
end
|
|
bat_now.ac_status = tonumber(helpers.first_line(string.format("%s%s/online", pspath, ac))) or "N/A"
|
|
|
|
if bat_now.status ~= "N/A" then
|
|
if bat_now.status ~= "Full" and sum_rate_power == 0 and bat_now.ac_status == 1 then
|
|
bat_now.perc = math.floor(math.min(100, (sum_energy_now / sum_energy_full) * 100))
|
|
bat_now.time = "00:00"
|
|
bat_now.watt = 0
|
|
|
|
-- update {perc,time,watt} iff battery not full and rate > 0
|
|
elseif bat_now.status ~= "Full" then
|
|
local rate_time = 0
|
|
-- Calculate time and watt if rates are greater then 0
|
|
if (sum_rate_power > 0 or sum_rate_current > 0) then
|
|
local div = (sum_rate_power > 0 and sum_rate_power) or sum_rate_current
|
|
|
|
if bat_now.status == "Charging" then
|
|
rate_time = (sum_energy_full - sum_energy_now) / div
|
|
else -- Discharging
|
|
rate_time = sum_energy_now / div
|
|
end
|
|
|
|
if 0 < rate_time and rate_time < 0.01 then -- check for magnitude discrepancies (#199)
|
|
rate_time_magnitude = math.abs(math.floor(math.log10(rate_time)))
|
|
rate_time = rate_time * 10^(rate_time_magnitude - 2)
|
|
end
|
|
end
|
|
|
|
local hours = math.floor(rate_time)
|
|
local minutes = math.floor((rate_time - hours) * 60)
|
|
bat_now.perc = math.floor(math.min(100, (sum_energy_now / sum_energy_full) * 100))
|
|
bat_now.time = string.format("%02d:%02d", hours, minutes)
|
|
bat_now.watt = tonumber(string.format("%.2f", sum_rate_energy / 1e6))
|
|
elseif bat_now.status == "Full" then
|
|
bat_now.perc = 100
|
|
bat_now.time = "00:00"
|
|
bat_now.watt = 0
|
|
end
|
|
end
|
|
|
|
widget = bat.widget
|
|
settings()
|
|
|
|
-- notifications for critical, low, and full levels
|
|
if notify == "on" then
|
|
if bat_now.status == "Discharging" then
|
|
if tonumber(bat_now.perc) <= n_perc[1] then
|
|
bat.id = naughty.notify({
|
|
preset = bat_notification_critical_preset,
|
|
replaces_id = bat.id
|
|
}).id
|
|
elseif tonumber(bat_now.perc) <= n_perc[2] then
|
|
bat.id = naughty.notify({
|
|
preset = bat_notification_low_preset,
|
|
replaces_id = bat.id
|
|
}).id
|
|
end
|
|
fullnotification = false
|
|
elseif bat_now.status == "Full" and full_notify == "on" and not fullnotification then
|
|
bat.id = naughty.notify({
|
|
preset = bat_notification_charged_preset,
|
|
replaces_id = bat.id
|
|
}).id
|
|
fullnotification = true
|
|
end
|
|
end
|
|
end
|
|
|
|
helpers.newtimer("batteries", timeout, bat.update)
|
|
|
|
return bat
|
|
end
|
|
|
|
return factory
|